stop-check Amendments to regulations on classification of houses and construction works English attachment

Circular No. 07/2019/TT-BXD dated November 7th, 2019 of the Ministry of Transport on amending, supplementing and replacing a number of articles of the Circular No. 03/2016/TT-BXD⛔ dated March 10, 2016 of the Minister of Construction regulating classification of construction works, and instructions for application of these regulations to investment and construction activities
Posted: 12/11/2019 7:49:49 AM | Latest updated: 8/7/2021 8:35:50 AM (GMT+7) | Newsletter #:4844
Effective: 1-Jan-2020 Status: Expired on: 15-Aug-2021
LuatVietnam This Circular is to add Article 1a to Circular No. 03/2016/TT-BXD⛔ in order to explain some terms and amends 03 Appendixes below:
• Appendix 1 “Classification of construction works based on capacity or importance levels”
• Appendix 2 “Classification of construction works based on structural measurement”
• Appendix 3 “Examples of determination of classes of construction works"
According to Clause 1 Article 1 of this Circular, “attic” refers to a floor inside a pitched roof space of which the entire or part of vertical sides is formed by pitched or folded roof surfaces, and vertical wall (if any) is restricted to 1.5 m in height from the floor level
“The number of stories in a building” (or construction work) includes all of floors above the ground level (including technical floor or loft), half/semi-basement, exclusive of the attic
In addition, “a loft” is not counted as a story of the building only when the loft is used for covering a staircase or elevator shaft, or hiding built-in equipment (if any), or is used as an intermediate space to reach the roof and serve rescue purposes, and makes up 30% at maximum of the dimensional area of the roof
With respect to a detached building, “a mezzanine” shall not be counted as a story of that building if the floor area of such mezzanine is not greater than 65% of the building area of the story underneath/
With respect to houses, home-type structures or buildings with multiple stories built on floor levels, mezzanines are not counted as stories thereof only when they are designed for use as technical spaces, cover no more than 10% of the building area of the story underneath, but less than 300 m2
This Circular takes effect from January 1st, 2020.
 
Xem Văn bản hợp nhất số 10/ VBHN-BXD ngày 30/12/2019.
Xem Văn bản hợp nhất số 05/ VBHN-BXD ngày 9/3/2020.
Effective notes
  • Please be informed that the attachments are neither translated nor included in the English file.
  • This Circular shall be expired from August 15th, 2021, replaced by Circular No. 06/2021/TT-BXD⛔ dated June 30th, 2021.